Pass the Michigan Journeyman Electrician exam

Michigan asks for 75%, the highest pass mark of the four states we cover, and tests its own Part 8 amendments and two licensing statutes next to the NEC. You bring bound books with factory tabs only. These 640 questions were written for that room.

75%
to pass · 80 questions · 150 min
640
verified questions · 485 knowledge, 155 calculation
NEC 2023 + Part 8
Michigan amendments, in force since 12 March 2024

Not in Michigan? See all states.

Independent, and not affiliated with the Michigan Department of Licensing and Regulatory Affairs or PSI.

How licensing works in Michigan

Michigan licenses electricians through LARA's Bureau of Construction Codes. You apply to LARA first ($40); once approved, you schedule the exam with PSI ($100, non-refundable). You get two attempts inside a year before you must reapply.

The one thing candidates get wrong: they study the NEC and skip the state layer. Part 8 rewrites 28 NEC sections, and PA 407 and PA 230 are on the exam. National prep does not cover any of it.

Licensing and exam: Journeyman Electrician

LARA Bureau of Construction Codes · exam by PSI
Eligibility
20+ years old · 8,000 h over 4+ years
Exam format
80 multiple-choice questions, one form
Pass mark
75%
Time
150 min
Try 20 real Michigan questions

2016 PA 407 §339.5707 and PSI bulletin 4376 (effective 20 Aug 2026), read 10 Sep 2026.

The Michigan exam, weighted the way PSI weights it.

PSI publishes no topic weights for Michigan, so we do not invent them. These are the thirteen topics named in the bulletin, with the book each one lives in.

Journeyman Electrician

80 items · 150 min · 75%
Grounding and bondingNEC + Part 8 · 250.104(B)
Overcurrent protectionNEC
Wiring methods and installationsNEC + Part 8 · 334.10
Boxes, cabinets and raceway fillNEC
ServicesNEC + Part 8 · 230.85
Feeders and branch circuitsNEC

Every practice question is tagged to one of these domains, so your study time follows the exam.

20 questions from the Michigan bank

Answer one and read the whole explanation, exactly as the app shows it after every question.

WorkUgo
Journeyman Electrician · Michigan sample
Michigan · LARA / PSI · NEC 2023
FREE SAMPLE
MICHIGAN JOURNEYMAN ELECTRICIAN · FREE SAMPLE TEST

5 questions from the Michigan bank

Answer, then read the full explanation exactly as the app shows it after every question: the rationale, why each other option fails, and the worked solution on calculations.

Real exam format: multiple choice, 4 options, one correct
Instant scoring, with full rationale on your first answers
Your score and where to focus next, right at the end
Free · about 15 minutes · no sign-up
640 verified questions
for the Michigan exam
Explanations cite
the NEC 2023 and the Michigan Part 8 rules
Works on a phone
between calls

What makes Michigan different

Michigan-amendment notes on every affected question

For 230.85, CSST bonding and NM cable you see the national rule and the Michigan rule side by side, so you learn the one the inspector enforces.

NEC 2023 · 230.85

Emergency disconnect for one- and two-family dwellings: three permitted forms, including a meter disconnect, with a marking requirement.

MICHIGAN PART 8 · 230.85

Removes the meter-disconnect option and prescribes the exact marking text. On the Michigan exam, the Part 8 version is the answer.

State-law questions written from PA 407, PA 230 and the Part 8 rules

70 items in the bank cover licensing, permits, inspection and administration, the topic national prep leaves out.

STATE-LAW · MICHIGAN
70 of 640
  • 2016 PA 407 · 339.5707
  • 2016 PA 407 · 339.5731(2)
  • 2016 PA 407 · 339.5737(2)
  • 1972 PA 230
  • Michigan Part 8 · 80.19(e)

Sample question 2 above is one of them.

Explanations teach where a rule lives in the book

You cannot tab or highlight, so every explanation names the article, table and column as well as what the rule says.

WHERE IT LIVES · SAMPLE QUESTION 3
Chapter 3 · Wiring methodsArticle 310Table 310.4(1)XHHW · wet-location column

Then 300.5(B) for why a buried raceway is a wet location. Two turns of the book, both named.

What a Michigan electrician earns

Wages for electricians employed in Michigan, all experience levels, union and non-union.

$36.67Median hourly wage
$76,270Median annual wage
23,530Electricians employed in Michigan

BLS OEWS, May 2025, Electricians (SOC 47-2111), Michigan statewide.

Choose Your Prep Plan

Pay monthly, or pay once and you're set. Full refund within 7 days on every plan.
Monthly

Monthly

$119 / mo

Renews monthly · cancel any time

Personalized study plan from your diagnostic, intensity and exam date
Dynamic cheat sheets: change one input and every step updates
Video tutorials by licensed journeymen and master electricians
650 exam questions: NEC-cited answers, calculations solved step by step
Interactive diagrams: trace fault current, switch circuits on and off
2 timed mock exams
Cancel any time from your profile
Start Monthly
Pay once

3-Month Pass

$279 one-time

Just $93/mo · save $78 vs. Monthly

Everything in Monthly, plus:
90 days of access, never renews
One payment, no monthly charges
Get the 3-Month Pass
Didn't pass? You're covered.

On Until You Pass, keep full access free until you pass, up to 12 months. Just send us your exam result.

Free job matching for every electrician

Create a profile and we'll introduce you to electrical employers hiring in your state. Free for anyone, with or without a plan.

We don't guarantee a job offer and never charge you for introductions.

Questions about the Michigan exam

Facts from the PSI bulletin, LARA and 2016 PA 407. Something missing? Write to us.

Contact us

75%. That is 60 of 80 questions right in 150 minutes, the highest pass mark of the four states we cover.

Start with 20 real Michigan questions

The sample needs no account. The full bank has 640 questions, each with the same explanation.